Functions
8.5 Setpoint calculation
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
179
If you must limit the speed depending on the direction of rotation, then you can define speed
limits for each direction.
Table 8- 9 Parameters for the speed limitation
Parameter
Description
p1082
Maximum speed (factory setting: 1500 rpm)
p1083
Speed limit, positive direction of rotation
(factory setting: 210,000 rpm)
p1085
CI: Speed limit, positive direction of rotation (factory setting: 1083)
p1086
Speed limit, negative direction of rotation (factory setting: -210,000 rpm)
p1088
CI: Speed limit, negative direction of rotation (factory setting: 1086)
Basic ramp-function generator
When compared to the extended ramp
-
function generator, the basic ramp
-
function generator has no rounding
times.
Changing the ramp-up and ramp-down times in operation
The ramping up and down
time of the ramp
-function
generator can be changed
during operation. The scaling
value can come e.g. from the
field bus.