Functions
8.9 Application-specific functions
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
223
Figure 8-29 Simplied diagram of the motor holding brake connections
Function
Figure 8-30 Motor holding brake function
Function after an ON command:
1. With the ON command, the inverter switches the motor on.
2. At the end of the "motor excitation build-up time" (p0346), the inverter issues the
command to open the brake.