EasyManua.ls Logo

Siemens SINAMICS G110M - Page 271

Siemens SINAMICS G110M
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Data backup and series commissioning
9.4 Write and know how protection
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
271
Activate and deactivate write protection
Procedure with STARTER
Proceed as follows to activate or deactivate the write protection:
1.
Go online.
2.
Open the inverter
shortcut menu.
3.
Activate or deactivate
write protection.
4.
Press the
Copy RAM to
ROMbutton to
retentively save the
settings
.
You have activated or deactivated write protection.
Parame-
ters
r7760
Write protection/know-how protection status
.00
Write protection active
p7761
Write protection (factory setting: 0)
0:
Deactivate write protection
1:
Activate write protection
Exceptions to write protection
Some functions are excluded from write protection, e.g.:
Activating/deactivating write protection
Changing the access level (p0003)
Saving parameters (p0971)
Safely removing the memory card (p9400)
Restoring the factory setting
Importing settings from an external data backup, e.g. upload from a memory card to the
converter.
The individual parameters that are excluded from the write protection, can be found in the
List Manual in Chapter "Parameters for write protection and protection of know-how".

Table of Contents

Other manuals for Siemens SINAMICS G110M

Related product manuals