Alarms, faults and system messages
11.3 Status LED overview
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
295
Explanation of status LEDs
An explanation of the various states indicated by the LEDs are given in the tables below.
Table 11- 1 Description of general status LEDS
Ready for operation (no active fault)
Commissioning or reset of factory settings
RED - On ORANGE - flashing
Firmware update in progress
Firmware updated is complete - power ON reset required
Fault occurred during firmware update
Incompatible firmware or incorrect memory card
Table 11- 2 Description of fieldbus communications LED
Cyclic data exchange (or fieldbus not in use - p2030 = 0)
Bus fault - configuration fault
RED - Flashing quickly Bus fault:
- no data exchange
- baud rate search - cannot detect the correct baud rate
- no connection - the connection between the Inverter and PLC has been lost
Table 11- 3 Description of SAFE LED
Safety function is enabled - but not active
YELLOW - Flashing
Safety function is active - no safety function faults have occurred
YELLOW - Flashing
The converter has detected a safety function fault and initiated a stop re-
Table 11- 4 Description of PROFINET communications LED
Link inactive with no data being transferred