Appendix
A.4 Frequently required parameters
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
315
Table A- 3
How to determine the firmware version of the Control Unit
Parameter
Description
R0018
Firmware version is displayed
Table A- 4
How to select the command and setpoint sources for the converter
Parameter
Description
p0015
Additional information is available in Section Wiring example for the factory settings (Page 75).
Table A- 5
How to set the ramp-up and ramp-down
Parameter
Description
p1080
Minimum speed
0.00 [rpm] factory setting
p1082
Maximum speed
1500.000 [rpm] factory setting
p1120
Ramp-up time
10.00 [s]
p1121
Ramp-down time
10.00 [s]
Table A- 6
This is how you set the closed-loop type
Parameter
Description
P1300 0: V/f control with linear characteristic
1: V/f control with linear characteristic and FCC
2: V/f control with parabolic characteristic
3: V/f control with parameterizable characteristic
4: V/f control with linear characteristic and ECO
5: V/f control for drives requiring a precise frequency (textile area)
6: V/f control for drive requiring a precise frequency and FCC
7: V/f control with parabolic characteristic and ECO
19: V/f control with independent voltage setpoint