07.97 7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
CPU load (as from SW 6)
1735
Default value Lower output limit Upper output limit Units
0 0 100 %
Active
at once
The processor capacity displays the remaining available CPU time online.
Measuring circuit type indirect measuring system
1790
Default value Lower output limit Upper output limit Units
0 0 32 767
Active
at once
This machine data displays the measuring circuit code number of the indirect measuring
system (motor).
Value table:
0 Voltage raw signals
1-7 Reserved
Measuring circuit type direct measuring system
1791
Default value Lower output limit Upper output limit Units
0 -1 32 767
Active
at once
This machine data displays the measuring circuit code number of the direct measuring system
if one is inserted.
Value table:
-1 No measuring system present
0 Voltage raw signals
1 Current raw signals (FDD)
2-7 Reserved
Data version
1797
Default value Lower output limit Upper output limit Units
0 0 32 767
Active
at once
Output of present data version (machine data list).
©