4-76
1010GCNFM-3C
Section 4
The chart below shows the sequence of the [F4] routine:
Procedure to clear Active memory only:
1. Turn off power (if it is currently on).
2. Press the <F4> key and keep it pressed while you turn on power. The prompt: [Clr Active Memory?
No] appears at the top of the screen.
3. Press the <Right Arrow> to access the [F4 Reset] option list. Press the <Down Arrow> to switch the
option list to [Clr Active Memory? Yes]. Press <ENT> to clear all Active Site Data (but not saved
Site Setups).
4. To restore operation, press <MENU> to access the installation menu. Create a new site setup or
recall a stored site setup.
5. Re-select any Meter Facilities items (e.g., RS-232 setup parameters).
Procedure to clear ALL Dynamic Memory:
1. Turn off power (if it is currently on).
2. Press the [F4] key and keep it pressed while you turn on power. The prompt: [Clr Active Memory?
No] appears at the top of the screen. Press the Down Arrow. Note that the prompt switches to [Clr
Saved Data? No].
3. Press the <Right Arrow> to access the F4 Reset option list. Press the <Down Arrow> to switch the
option list to [Clr Saved Data? Yes].
CAUTION: Before proceeding further it is essential to understand that this function elimi-
nates
ALL data stored in RAM. This means that all saved site setups including
the site data of a flow-calibrated site will be erased! In addition, the entire
Datalogger file plus any custom factory or user-created pipe or transducer
tables will be eliminated. The impact of this is such that we strongly recom-
mend that you consult technical service before continuing with this proce-
dure. Be aware that you will have to create a new Site Setup, re-enter all site
specific parameters including pipe or transducer tables, plus all desired Meter
Facilities entries.
4. Press <ENT> to clear all Dynamic Memory.
5. Create a Site Setup before attempting to access other menu items.
6. To restore operation, press <MENU> to access the installation menu. Create a new site setup and
complete the installation procedure.
7. Re-select desired Meter Facilities items (e.g., RS-232 setup parameters).
[Power On/Off + F4] [Clr Active Memory?]
No
Yes
[Clr Saved Data?] No
Yes

Table of Contents

Questions and Answers: