4-87
1010GCNFM-3C
Section 4
You can use the <Right Arrow> to move the cursor back to a number if you need to re-type it. Press the
<CLR> key to remove the current setting.
To set the Date:
1. Press the <Right Arrow> to enable numeric entry.
2. Use the numeric keys to type the date (MM.DD.YY).
3. Press <ENT> to store the date. This moves the cursor to [Time].
Time
The Time command sets the hours and minutes for the meter’s internal clock/calendar. Enter the time
using the [HH.MM.SS] format. Replace HH with 2 digits to indicate the hour (use 24-hr. clock format).
Replace MM with 2 digits to indicate the minutes. Replace SS to indicate the seconds. You also have to
type the period (.) separator between each set of digits. For example, you would enter ten minutes after
two o’clock in the afternoon by typing: 14.10.00 You can use the <Right Arrow> to move the cursor back
to a number if you need to re-type it. Press the <CLR> key to remove the current setting.
To set the clock:
1. Press the <Right Arrow> to enable numeric entry.
2. Use the numeric keys to type the time (HH.MM).
3. Press <ENT> to store the time. This moves the cursor to [RS-232 Setup].
4.12.8 RS-232 SETUP
Use the [RS-232 Setup] menu to set the operating parameters of the serial I/O port. Settings include
baud rate, parity, data bits, line feed, network I.D number and waiting period before a RTS time-out. Only
activate the RS-232 output if you intend to transmit serial data. This will avoid burdening the system with
unnecessary data transferals while it is performing flow computations.
NOTE: The RS-232 stop bit implementation is fixed. If you are using a communication program,
such as Windows 3.xx Terminal or Windows 95/98/NT/2000/XP HyperTerminal, that in-
cludes a field for stop bits, select 1 stop bit.
Siemens Dual Path SITE 1
Baud Rate 9600
Parity odd
Data Bits 7
Line Feed Yes
Network ID 0
RTS Key Time 0.2 Secs
RS-232 Setup
Match to connected Device

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SITRANS FUG1010 IP65 NEMA 4X and is the answer not in the manual?

Siemens SITRANS FUG1010 IP65 NEMA 4X Specifications

General IconGeneral
BrandSiemens
ModelSITRANS FUG1010 IP65 NEMA 4X
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals