5-4
1010GCNFM-3C
Section 5
5.2 REFLECT MODE - MOUNTING FRAMES AND SPACER BAR
The combination of a spacer bar with mounting frames is the easiest way to mount in Reflect Mode. The
result is a rigid structure that eliminates spacing measurements, and maintains the transducer-to-trans-
ducer geometry. In addition, reflect mounting allows you to move the entire assembly while maintaining
the original transducer spacing.
1. Perform all required menu steps until the flow computer issues the number index and prompts you to
press to finish the transducer install routine. Stop at this point.
Note the number index value displayed in the Pick/Install menu. You will use this number to properly
space the transducers. Check to ensure that you have a matched set of transducers. They both should
have the same S/N number but marked with either an “A” or “B” (e.g., 100A and 100B).
ENT
Optional on larger
pipes, you can link
straps to surround pipe
Spacer Bar Platform &
Clam
in
Screw
Mounting Strap
positioned around
Mounting Frame
Space Bar
Front View
Mounting Strap
d
ustin
Screw
INSTALLATION - REFLECT MOUNT WITH FRAMES AND SPACER BAR
NOTE: Minimum Ltn 0.75 in. (18 mm)
Mounting Strap
Transducer Clamping
Screw
ote optional 2nd
Mounting Strap
shown.
arger pipes may
need an additional
strap for a more
secure mount
Spacer Bar
Spring Clip
(Not present on some
models)
1012 Series
Mounting Frame
Spacer Bar
Platform and
clamping screw
Spring Clip
(Not present on
some
models)
Transducer Clamping
Screw
Spacer Bar
Spacer Bar
Platform and
clamping screw
Mounting Strap
Note operational
2nd Mounting Strap
shown.
Larger pipes may
need an additional
strap for a more
secure mount.
1012 Series
Mounting Frame