Manual Addendum
1010FMA-57
A-2
The example below demostrates how to calculate the AnCal flow rate based on the desired pulse output
frequency and the entered PGEN (Pulses / Unit volume) setting:
For PGEN setting = 53 Pulses /CU FT and a desired frequency = 1000 Hz
1. Temporarily change flow rate units to CU FT / SEC (Use same volume units as Totalizer.)
2. Set AnCal = 1000 / 53 = 18.868 CU FT / SEC
3. 1000 Hz frequency should now be observed on the PGEN output.