Installation Instructions
CC129A-7
4
z After determining the best sheet cutting pattern from suggestions above, mark the pipe for the
starting edge of the dry couplant sheet position.
z Partially peel the sheet backing 1 to 2 inches from the starting edge, then carefully locate and
press against the pipe surface.
zWhile pressing firmly and sliding your hand against the sheet (along the pipe surface), slowly
peel away the backing such that it prevents the trapping of air.
z Apply the film slowly and carefully so that the sheet does not wrinkle, stretch or overlap,
especially under the transducer contacting surfaces.
z Use the wooden hand roller supplied to smooth the film and assure adhesion to the pipe surface.
zApply additional layers (if required) while avoiding any seams under the transducers.
zUse the wooden hand roller on each layer applied.
z Record final thickness of CC129-1A (from Table 1) for later entry into the 1010GC flowmeter.
CN4973 February 2005
ROLL IN LINE WITH PIPE AXIS