Installation Instructions
1012WS-1-7 Weld Seal Installation Instructions
Inspection Proc Test Proc Prep By Date Approval Initial
Date
NA NA G VanPopering 10/29/01 Engineering: DR 05/04/05
Valid By: IR 05/04/05
Covered Assemblies:
1012WS Single Enclosure
(Reflect and Direct-X Modes)
Change Log
Document Rev Change Description Date Change By Approved
A/- Original Release 04/18/02 GV MF
A/1
(CN4763) Added reference to Fixed Spacer, CC110, Clean Gasket
06/24/03 GV MF
A/2
(CN5000) Added reference to proper unpacking and disassembly
04/25/05 GV MF
B
(CN5157) Changed LOGO to Siemens. Updated Fig 3-B
08/14/06 GV MF
Tools Required General Notes
1) Hex Key Set S.A.E. 5/32 and 1/8 In.
2) Phillips Head Screwdriver #2
3) 7/16” Socket Deep throat
4) 7/16” Wrench Open end
5) Razor Blade
6) Flat Blade screwdriver
7) Torque limiting driver/wrench in/lbs
8) Grease Pencil For marking pipe
Compounds Used
1) CC128 Super Lube
2) CC110 G662 Silicone Grease
Pre Assembly Note:
1. Using the installation menu and the procedure outlined in the FDC Field Manual, confirm
that you have the appropriate transducers and Enclosure Set for operation on the chosen
pipe.
2. Select mounting location
2.1 Choose location that remains full at zero flow.
2.2 Where possible, locate enclosure ass’y 10 pipe diameters or more from elbow or valve to
ensure fully developed and stable flow profile.
2.3 On horizontal pipe sections, select horizontal plane to avoid sediment or gas blockage of
ultrasonic beam.
2.4 Multiple beam applications see drawing 1012WS-8 and/or Fig 1-1 of this procedure.
3. Prepare pipe for enclosure mounting.
3.1 Remove grit, corrosion, coating or heavy paint. (Avoid grinding which could cause distortion
of the pipe surface
3.2 Clean and degrease surface.
3.3 Do not mount over frost.
3.4 Do not mount on the seam of the pipe.
3.5 Locally, smooth the pipe surface to accept the transducers. Use the abrasive pad provided.
(Note: It is recommended two people be available to perform
this procedure.)
1012WS-1-7