Maintenance and service
9
9.1 Maintenance
The device is maintenance-free, however a periodic inspection according to pertinent
directives and regulations must be carried out.
An inspection can include check of:
Ambient conditions
Seal integrity of the process connections, cable entries, and cover screws
Reliability of power supply, lightning protection, and grounds
9.2 Replacing the battery
The internal battery pack used with SITRANS F 1010 portable flowmeters may be removed
and replaced when needed.
Battery Pack Removal/Replacement
1. Disconnect power to the unit.
2. Open the flowmeter cover by releasing the two side cover latches.
3. Make sure power to unit is turned off.
FUP1010 IP67 Portable Flowmeter
Operating Instructions, 02/2010, A5E02951522A Revision 01
111