Positioning Track Assemblies
1. Wrap a length
of the Mylar spacing guide around the pipe and against the end of the track
assemblies. Ensure that the spacer guide edges on both sides align. Arrange so that one
end overlaps the other by at least 8 cm (3 inches). Trim to fit if necessary, but in order to
keep the end square, be sure not to trim at the overlapping end.
① Trim material from inner edge if necessary
② Mylar Spacing Guide
③ 8 cm (3-inches) Overlapping Edge
Figure 5-25 Wrapping the Mylar Spacing Guide around pipe (End View)
2. Remove the spacer
guide. Measure or fold spacer guide to find its halfway distance. Mark
a center line and then tape spacer guide to pipe.
① Overlap Edge ③ Mark on Spacing Guide
② Mark (or fold) exactly at half-way point ④ Circumference
Figure 5-26 Finding the Halfway Distance
Connecting
5.2 Sensor Wiring
FUP1010 IP67 Portable Flowmeter
Operating Instructions, 02/2010, A5E02951522A Revision 01
57