7.6 Memory Control
Introduction
Memory Control is a reference menu that shows the amount of bytes of data memory left. The
data memory capacity depends on the number and complexity of the site setups stored in
memory and the size of the current Datalogger file.
The [Memory Control] menu is located in the [Meter Facilities] menu.
Table 7-5 Memory Control Menu
Log Memory Left→ XXXXXXX
Memory Map→ No
Yes
Defragment→ No
Yes
Log Memory Left
This view only menu cell shows the minimum remaining number of characters available for
Datalogger and site storage. When the Datalogger is enabled for circular mode, the meter
allocates all memory
left except for two conventional empty sites required for Datalogger use.
To view the amount of data memory bytes available press <Right Arrow>.
Memory Map
Selecting YES for this item enables a snapshot display of current memory usage. In this
display, the asterisk indicates a used block, a space indicates a free block, while a dash
character indicates unused filler.
Defragment
Selecting YES for this item consolidates memory data blocks into contiguous storage;
collapsing the filler regions. You may be able to use an additional block for site or Datalogger
storage as a result. Use this command if you seem to be out of memory even though the [Log
Memory Left] item indicates free capacity.
Functions
7.6 Memory Control
FUP1010 IP67 Portable Flowmeter
86