Alarm, error, and system messages
8
8.1 Alarm Letter Codes and Descriptions
The following alarm codes appear on the main display of the flowmeter.
Table 8-1 Alarm Codes and Descriptions
Letter Codes Alarm Code Description
SPACE Spacing Transducer spacing may need adjustment
EMPTY Empty Pipe is empty
HI/LO Rate Flow above High setting or below Low setting
FAULT Fault Three continuous seconds without new data update
AER Aeration Current aeration percentage exceeds the alarm set point
MEMRY Memory Last valid reading for a selected interval during Fault condition
MAKUP Makeup In-Process Makeup occurred
The following alarm codes appear in the Datalogger status messages:
I Interface Liquid Vs exceeds interface alarm set point
P Pig Pig passage detected (optional)
Z ZeroMatic ZeroMatic signal occurred
The displays shown below indicate where the Alarm Codes appear on the screen. Press <UP>
or <DOWN> Arrows to change screen views.
Alarm Codes
FUP1010 IP67 Portable Flowmeter
Operating Instructions, 02/2010, A5E02951522A Revision 01
109