Chapter 16 Engineering Setup
286
Setup Relating to Operations From the Control Panel
A/B Bus: When the [XPT HOLD] button is pressed, turning it on,
cross-point hold is enabled for the A and B buses only.
All Bus: When the [XPT HOLD] button is pressed, turning it on,
cross-point hold is enabled for all buses used on the operating bank.
(A/B buses, Key 1 to Key 4 buses, Utility 1/2 buses, external DME
bus, DME Utility 1/2 buses)
Setting trackball, joystick, and double-click sensitivity
Use the following procedure.
1
In the Panel>Operation menu, press the [Sensitivity].
The Sensitivity menu appears.
The status area shows a list of the items with their settings.
2
Make the following settings as required.
Trackball and Z-ring sensitivity in normal mode: In the <Trackball
Normal Mode> group, select [×1], [× 2], or [×4].
Trackball and Z-ring sensitivity in fine mode: In the <Trackball Fine
Mode> group, select [
1
/
2
], [
1
/
4
], or [
1
/
8
].
Joystick sensitivity in normal mode: In the <Joystick Normal Mode>
group, select [× 1], [× 2], or [× 4].
Joystick sensitivity in fine mode: In the <Joystick Fine Mode> group,
select [
1
/
2
], [
1
/
4
], or [
1
/
8
].
Touch sensitivity for recalling menus by double-clicking buttons: In
the <Double Click> group, select [Fast], [Normal], or [Slow].
Specifying main split fader
In the <Main Split Fader> group of the Panel>Operation menu, select
[Left] or [Right].
Setting the macro execution mode
Use the following procedure.
1
Press [Macro] in the Panel>Operation menu.
The Macro menu appears.
2
In the <Macro Execution Mode> group, select the macro execution mode.
Normal: normal execution mode
Step: step execution mode