Chapter 16 Engineering Setup
334
Setup Relating to DCU
CTL (Control): CTL pulses or timer counter pulses are used. Use this
only for a tape on which no timecode is recorded.
The displayed tape position is based on the reference signal specified here.
5
Using any of the following methods, specify the VTR constants.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
6
Press [Set].
A numeric keypad window for hexadecimal input appears.
7
Set the VTR constants using values in the range 00 to ff.
8
Press [Enter].
This confirms the settings.
Knob Parameter Adjustment Setting values
1 Item Item selection 1 to 16
Block Byte Setting item
BLOCK 1 1 HI-BYTE (DEVICE TYPE)
2 LO-BYTE (DEVICE TYPE)
3 HI-BYTE (FRAME) (PREROLL TIME)
4 LO-BYTE (FRAME) (PREROLL TIME)
5 EDIT DELAY (FRAME)
6 EE DELAY (FRAME)
7 OVER RUN (FRAME)
8 TRAJECTORY
BLOCK 2 1 TC READ DELAY (FRAME)
2START DELAY (FRAME)
3 AFTER SYNC DELAY–
4 AFTER SYNC DELAY+
5MODE1
6MODE2
7 MAX PRRL SPEED
8 QUICK PVW PRRL TIME (FRAME)

Table of Contents