ELECTRICAL SYSTEM 15-8
GENERATING SYSTEM
INSPECTION
REGULATED VOLTAGE
• Insert the needle pointed probes
A to the condenser coupler
1.
+ Prove: Red lead wire
- Prove: B/W lead wire
• Connect the multi-circuit tester or electric tachometer to the
high-tension cord. (!2-19)
• Kickstart the engine and keep it running at 5 000 r/min.
• Measure the DC voltage using the multi-circuit tester. If the
voltage is not within the specified value, inspect the magneto
and regulator/rectifier. (! 15-9, -10)
# Regulated voltage (Charging output):
13.5 – 15.0 V at 5 000 r/min
" 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
$ Tester knob indication: Voltage (%)
Magneto
Regulator/Rectifier
SCR
IC
Load
Condenser