EasyManua.ls Logo

Suzuki RM-Z450 - Generating System; Inspection

Suzuki RM-Z450
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL SYSTEM 15-8
GENERATING SYSTEM
INSPECTION
REGULATED VOLTAGE
Insert the needle pointed probes
A to the condenser coupler
1.
+ Prove: Red lead wire
- Prove: B/W lead wire
Connect the multi-circuit tester or electric tachometer to the
high-tension cord. (!2-19)
Kickstart the engine and keep it running at 5 000 r/min.
Measure the DC voltage using the multi-circuit tester. If the
voltage is not within the specified value, inspect the magneto
and regulator/rectifier. (! 15-9, -10)
# Regulated voltage (Charging output):
13.5 – 15.0 V at 5 000 r/min
" 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
$ Tester knob indication: Voltage (%)
Magneto
Regulator/Rectifier
SCR
IC
Load
Condenser
Condenser
DCV
RB/W
B/W
O

Table of Contents