CYLINDER HEAD, CYLINDER AND PISTON 6-8
CAM WEAR
• Measure the cam height
H using the micrometer.
• Replace a camshaft if the cams are worn to the service limit.
" Cam height
H
Service Limit IN.: 35.23 mm (1.387 in)
EX.: 34.03 mm (1.340 in)
# 09900-20202: Micrometer (25 – 50 mm)
CAMSHAFT JOURNAL WEAR
• Determine whether or not each journal is worn down to the
limit by measuring the oil clearance with the camshaft
installed in place.
• Use the plastigauge to read the clearance at the widest por-
tion, which is specified as follows:
# 09900-22301: Plastigauge
09900-22302: Plastigauge
• Tighten the camshaft journal holder in ascending order of
numbers to the specified torque. (!6-29)
$ Camshaft journal holder bolt:
10 N·m (1.0 kgf-m, 7.0 Ib-ft)
NOTE:
Do not rotate the camshaft with the plastigauge in place.
• Remove the camshaft journal holder, and read the width of
the compressed plastigauge with envelope scale. This mea-
surement should be taken at the widest part.
" Camshaft journal oil clearance:
Service Limit (IN. & EX.): 0.150 mm (0.0059 in)