Chapter D
Chapter DAdjustment mode
176
W301-0411E
6.2 Processing Depending on Setting Status
In: With detector or with function
Out: With no detector or with no function
The default setting is as listed in the Table 6.2.1.
Table 6.2.1 Default setting of the optional items
Optional item Default
Swing angle Detector is not present (Out)
Anemometer Detector is not present (Out)
Main Press Detector is not present (Out)
Jack Press Detector is not present (Out)
Working Range Limitation With no function (Out)
Radio Control With no function (Out)
%-Display Utilization With no function (Out)
6.3 Processing at Setting without Detector
- When swing angle detector is not present: "Swing Angle"
(1) Swing-angle-related error check will not be performed.
(2) Setting of swing angle limit is disabled with the work range limit function. The setting itself will not be
displayed.
(3) With the actual hoist medium load check cancel function (#2784), the canceling of error E2023 is disabled.
(4) LCD swing position and angle display will not be performed.
- When anemometer is not present: "Anemometer"
LCD will not show the wind speed indication.
- When main pressure detector is not present: "Main Press"
LCD will not show the main pressure indication.
- When jack supporting pressure detector is not present: "Jack Press"
LCD will not show the jack supporting pressure indication.