Page #55 background imageLoading...
Page #55 background image
43
W301-0411E
Chapter B Chapter B
User Mode
B-4 Other Functions
There are other 5 functions as shown below.
1. Working range limit function
2. TARE function
3. Mute alarm function
4. Fuel consumption display function
5. User control menu
Eco mode selection (Eco1, Eco2)
Winch drum rotation buzzer selection
Fuel consumption history display
Selection of the winch to be used
Adjustment of display panel contrast
Transmission of Telematics alarm data
Each function is as follows:
4.1 Working Range Limit Function
NOTIC
E
If the work range limit is registered too close to an obstacle, the machine can hit the
obstacle depending on the crane configuration and operation methods.
Consider a sufficient allowance when you register the limit.
The work range limit function restricts the operation of
the crane to the pre-registered boom angle (upper
limit, lower limit), lifting height, load radius, and swing
angle (left, right). Use this function when operating the
machine in a place where there are obstacles around
the machine or when requiring the working range limit
of the boom.
When the crane reaches the registered working range,
the limit function works as shown below:
Working range limit
function
Crane state
Boom angle upper limit
Boom angle lower limit
Lifting height limit
Load radius limit
Left swing limit
Right swing limit
Crane stops
automatically.
AML built-in buzzer
beep-beep-beep
(Short beeps repeat for
3 seconds. )

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tadano AML-C and is the answer not in the manual?

Tadano AML-C Specifications

General IconGeneral
BrandTadano
ModelAML-C
CategoryMeasuring Instruments
LanguageEnglish