STEP EXCITE: Service & maintenance manual - rev. 1.4
Page 9.20
9.3.4.4. View Errors
For every error generated by the machine, the error history log records the information in the table
below:
• Counter
• Error code
• date (dd-mm-yyyy – hh:mm) (NOT present on ARM display board models)
• Current when the error occurred
• Distance in km when the error occurred
The correspondence between error codes and descriptions is given in the table below:
Error Code Description
1
OVERHEATING: this condition occurs when the temperature detected by the
sensor on the circuit board exceeds 90°C.
8
OVERVOLTAGE: this condition occurs when the +12 Vdc voltage goes above
13.7 Vdc (only on the 500i, 700i and 700i Emodels).
Use the + effort level key to advance to the next error, otherwise the message with the details of the
current error will continue to reappear.
9.3.5. STANDARD SETTINGS
This function clears the operating data of the machine and simultaneously resets the brake board
parameters to their default values. To access this menu, when the display shows:
STANDARD SETTINGS ?
press ENTER, the following message appears:
CONFIRM ?
Press ENTER again to reset all parameters to their default values, or return to the upper menu level
by pressing CLEAR for a few seconds.
This function does not alter the language and the TV standard setting.
9.3.6. LOW KIT MENU
This function directly accesses the firmware of the brake board. To access this menu, when the
display shows:
LOW KIT MENU
press ENTER. This function is structured as follows: