Page 6.31
(3) Check that the cardio receiver has been assembled properly as described in the procedure 7.4.
Disassembling the cardio receiver”.
(4) To check for electromagnetic noise near the machine, use Test Box Excite as detailed here
below. You can use one of the following cables ELT-16 (0WC00518AB), CBQ-28
(0WC00390AC) or TRM-28 (0WC00336AC) as connection cable.
The circuit lights the LED for each heart beat and/or disturbance received: in this way it is
possible to determine whether there is any interference, and identify its sources.
(5) Check the battery power level, using a tester if possible. Otherwise use a receiver or another
reference machine to check the operation up to a distance of about 80 cm from the receiver.
HFU
Receiver
TEST BOX
EXCITE
HR receive
r