4-54 4252490-Rev A
ELECTRICAL
4
Horn Switch
Removal and Installation
See Figure 4-42.
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
4. Remove instrument panel. (See “Instrument Panel”
on page 4-52.)
Figure 4-42
NOTES
Note orientation of horn switch to ensure correct
installation.
Label all wires before disconnecting to ensure
correct installation.
5. Loosen wire hold-down screws (4) on horn switch
(5).
6. Disconnect wires (2 and 3).
7. Remove horn retainer nut (1), and remove horn from
instrument panel.
Installation Note
Install horn switch by reversing the order of removal.
Key Switch
Removal and Installation
See Figures 4-43 and 4-44.
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
4. Remove instrument panel. (See “Instrument Panel”
on page 4-52.)
Figure 4-43
NOTES
Note orientation of the key switch to ensure correct
installation.
Label all wires before disconnecting to ensure
correct installation.
5. Remove key.
6. Disconnect wire connectors (2 and 3) from
key switch (1).
TN3888
2
4
1
3
5
TN3889
2
3
1