4-64 4252490-Rev A
ELECTRICAL
4
Figure 4-64
NOTE
Label all wires before disconnecting to ensure correct
installation.
5. Locate correct warning light.
6. Disconnect wire connectors (5 and 6).
7. Remove nut (4).
8. Remove warning light.
Installation Note
Install warning lights by reversing the order of removal.
Fuel Shutoff Timer
Removal and Installation
See Figure 4-65.
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
Figure 4-65
NOTE
Label all wires before disconnecting to ensure correct
installation.
4. Disconnect wire connector (5).
5. Remove screw (1), nut (2), and two washers (3), and
remove fuel shutoff timer (4).
Installation Notes
• Apply dielectric grease (Jacobsen PN 365422) to any
wire connectors disconnected.
• Use new cable ties to secure wire connectors and
wire harness.
• Install fuel shutoff timer by reversing the order of
removal.
TN3905
4
5
6
TN4033
5
4
2 31