HYDRAULICS
4252490-Rev A 6-21
6
Raise Circuit Schematic
See Figure 6-14.
Figure 6-14
1 Return Oil to Oil Cooler and Hydraulic Tank 2 Operating Pressure Oil from Reel Valve Unit (Port T)
Lift Valve
TN3070
Right Lift Cylinder
Relief Valve
1250 psi
1
2
Left Lift Cylinder
Center Lift Cylinder
PT
Solenoid Valve
Check
Valve
AB
BA
BB
AA
Top
Sequence
Soft Drop
Valve
Bottom Sequence
Delay Valve
Operating Pressure Oil
Return Oil