4-60 4252490-Rev A
ELECTRICAL
4
Installation Notes
Apply dielectric grease (Jacobsen PN 365422) to any
wire connectors disconnected.
Use new cable ties to secure wire connectors and
wire harness.
Install the 12V accessory socket by reversing the
order of removal.
Fuses
Removal and Installation
See Figure 4-56.
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
Figure 4-56
4. Remove fuse cover (1).
5. Locate correct fuse.
6. Remove fuse.
Installation Note
Install fuse(s) by reversing the order of removal.
Relays
Removal and Installation
See Figure 4-57.
Figure 4-57
NOTES
Engine stop relay not shown.
This procedure applies to the following relays:
Engine stop relay (gasoline models) (1)
Glow plug relay (2)
Start relay (3)
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
4. Locate correct relay.
5. Pull relay straight up and out of relay base (4).
Installation Note
Install relay(s) by reversing the order of removal.
TN4033
1
TN3895
1
2
3
4

Table of Contents