4-60 4252490-Rev A
ELECTRICAL
4
Installation Notes
• Apply dielectric grease (Jacobsen PN 365422) to any
wire connectors disconnected.
• Use new cable ties to secure wire connectors and
wire harness.
• Install the 12V accessory socket by reversing the
order of removal.
Fuses
Removal and Installation
See Figure 4-56.
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
Figure 4-56
4. Remove fuse cover (1).
5. Locate correct fuse.
6. Remove fuse.
Installation Note
Install fuse(s) by reversing the order of removal.
Relays
Removal and Installation
See Figure 4-57.
Figure 4-57
NOTES
Engine stop relay not shown.
This procedure applies to the following relays:
• Engine stop relay (gasoline models) (1)
• Glow plug relay (2)
• Start relay (3)
1. Park the mower safely. (See “Park Mower Safely” on
page 1-6.)
2. Disconnect the negative (–) battery cable at the
battery.
3. Remove instrument panel cover. (See “Instrument
Panel Cover” on page 9-13.)
4. Locate correct relay.
5. Pull relay straight up and out of relay base (4).
Installation Note
Install relay(s) by reversing the order of removal.