5. SYSTEM MODE EO18-33027
5.11 RFID Module Setting
5-96
5.11.4.6 CALIB. MODE
・ OFF
・ ON
This parameter is to select whether the RFID calibration function is enabled or not.
When enabled (ON), the AGC value (CALIB. AGC) and the distance to the read/write position (CALIB.
POSITION) obtained through an RFID calibration become effective. Also, the printer will
automatically feed RFID media forward/backward for the distance specified by CALIB. POSITION
parameter before writing/reading RFID tag. Therefore, @003 command’s parameters “a” and “bbbb”
become invalid. (For details of the @003 command, refer to the External Equipment Interface
Specification for the B-EX Series.)
When the values obtained through an RFID calibration are set, this parameter will automatically turn
ON.
Applicable model: B-EX4T1-G/T-QM/CN C1.4 or later
For details of the RFID calibration, refer to Section 6.7 RFID CALIBRATION.
5.11.4.7 CALIB. AGC
By performing an RFID calibration, an AGC (response level from an RFID tag) value is automatically
obtained and set. This parameter is effective only when the CALIB. MODE parameter is set to ON.
Data write/read is performed only for the tags having the AGC value equal to or larger than the AGC
value set for this parameter. When the AGC value is less than the one set for this parameter, RFID
WRITE ERROR occurs.
Applicable model: B-EX4T1-G/T-QM/CN C1.4 or later.
For details of the RFID calibration, refer to Section 6.7 RFID CALIBRATION.