6. ON LINE MODE EO18-33027
6. 11 LCD MESSAGES AND LED INCATIONS
6-28
Remaining memory size of the external
USB memory
Remaining memory size for PC command
storage area in the internal memory
Remaining memory size for writable
character storage area
(*1) When there is command error in received command, up to 42 bytes of error command, starting from
the command code, are shown on 3
rd
and 4
th
lines of the LCD.
(However, [LF] and [NUL] are not displayed. Also, 43rd bytes and later are not displayed.)
Display example
(Example 1)
[ESC] PC001;0A00,0300,2,2,A,00,B [LF][NUL]
LCD Display
(Example 2)
[ESC]T20G30[LF][NUL]
LCD Display
(Example 3)
[ESC] PC002;0100,0300,15,15,A,00,00,J0101,+000000000A,Z10,P1[LF][NUL]
LCD display
(*2) When a command error is displayed, the code other than 20H - 7FH and A0H - DFH is displayed as
“?” (3FH).
(*3) When the ribbon near end detection is enabled, the error LED blinks at a 1-second interval (ON for
500 msec. OFF for 500 msec.) while the printer is in a ribbon near end state.
(*4) The battery check does not work when the printer is being reset and the RTC is not mounted.
(*5) It is necessary to follow the procedure below to use RTC function under a low battery condition.
Turn off the printer power while the printer is in an error state. Start the printer in the system mode,
set the date and time for the RTC again, then reset the printer to place the printer in online state.
* The printer can print the programmed date and time until it is turned off.
PC001;0A00,0300,2,2,A
,00,B
T20G30
PC002;0100,0300,15,15