4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO18-33027
(Revision Date: Sept. 5, 2014)
4.10 UHF RFID KIT (B-EX700-RFID-U4-US/EU/CN-R)
4-48
APPLICABLE MODEL
(1) This optional device is intended for the following models:
B-EX4T Series
Be careful not to install this product in any other models than above.
(2) The countries where the use of this device is allowed are as follows:
Model Name
Frequency Band
Applicable Countries
B-EX700-RFID–U4-US-R
UHF 902.75 to 927.5MHz
U.S.A., Canada
UHF 918.25 to 925.75MHz
Australia
UHF 920.9 to 923.3MHz
Korea
UHF 922.25-927.25MHz
Taiwan
PACKING LIST
All the following parts are supplied with the kit. Make sure you have all items shown below.
If any part is missing, please contact your TOSHIBA TEC sales agent.
RFID Module
M-3x6 Screw (1 pc)
Interface Cable (1 pc.)
Ribbon Guide (1 pc.)
Bush (1 pc.)
Cable ties (2pcs.)
Installation Manual
(1 copy)
EARTH PLATE ( 1 pc)
Shield Label
F
C
R
Cover Mylar
RFID Paper Guide