6.2.4.5 Scaling: Measuring units per revolution (PNU 65006)
This parameter sets the resolution of the measuring system in [steps per revolution], see also Chapter
6.2.3.11 on Page 48.
PNU
65006
Meaning
Resolution in steps per revolution
Data type
Unsigned32
Access
read/write
Activation
PNU 972
Storage
PNU 971
6.2.4.6 Scaling: Total measuring range (PNU 65007)
This parameter defines the total number of steps over the entire measuring range of the measuring
system, see also Chapter 6.2.3.11 on Page 48.
PNU
65007
Meaning
Total measuring range in steps
Data type
Unsigned32
Access
read/write
Activation
PNU 972
Storage
PNU 971