6.2.3.11.2 Scaling: Total measuring range
Defines the total number of steps (measuring range in steps) of the measuring system, before the
measuring system starts at 0 again.
Data type
Unsigned32
Lower limit
4 steps
Upper limit
536 870 912 steps
Default
536 870 912
The actual upper limit value to be entered for the measuring range in steps depends on the measuring
system design and can be calculated using the formula below. As the value "0" is already counted as
a step, the end value = measuring range in steps - 1.
Measuring range in steps = steps per revolution * number of revolutions
For the purposes of calculation, the parameters Steps/Revolution and Number of Revolutions can
be taken from the measuring system nameplate.
When entering parameter data, ensure that the parameters “Measuring range in
steps” and “Number of steps per revolution” are selected such that the result is
not a decimal number.
6.2.3.12 Tolerated sign-of-life faults (V3.1)
Alternatively, this parameter can also be set during operation via an acyclic parameter access to the
master sign-of-life error function PNU 925, see Page 65.
The max. number of permissible errors of the master sign-of-life counter is defined with this
parameter. The parameter Compatibility mode V3.1 must be set to enable for this purpose. If
the max. number of permissible errors is exceeded, the error code 0x0F02 is transmitted instead of
the position via signal G1_XIST2.
Data type
Unsigned8
Lower limit
0
Upper limit
255
Default
1