Parameterization and configuration
TR-Electronic GmbH 2019, All Rights Reserved Printed in the Federal Republic of Germany
Page 52 of 154 TR - ECE - BA - GB - 0139 - 02 11/21/2019
6.2.3.17 Preset value (PNU 65000)
Alternatively, this parameter can also be set during operation via an acyclic parameter access to the
parameter number PNU 65000, see Page 57.
The zero point of the measuring system can be adapted to the mechanical zero point via the preset
value parameter and is set either as an absolute value or as a relative value, in relation to the
position output, during execution of the preset function, see Chapter “Preset function” on Page 70.
The transmitted value is interpreted differently, depending on the preset mode set:
Preset mode = absolute
Transmitted value is interpreted as an Unsigned32 type
Preset mode = relative
Transmitted value is interpreted as an Integer32 type in two's complement form
-2
31
(relative), 0 (absolute)
+2
31
–1 (relative), 2
31
(absolute)