Parameterization and configuration
TR-Electronic GmbH 2019, All Rights Reserved Printed in the Federal Republic of Germany
Page 46 of 154 TR - ECE - BA - GB - 0139 - 02 11/21/2019
6.2.3.5 Code sequence
Danger of death, severe personal injury and/or material damage due to a
jump in the absolute value when the code sequence is changed!
The internal calculation algorithm results in different absolute positions
for the counting direction settings CW and CCW.
Therefore, after changing the rotational direction, verify the correct
function by a protected test run first. Under certain circumstances, the
output position must be adjusted via the preset function.
Alternatively, this parameter can also be set during operation via an acyclic parameter access to
function control PNU 65004 Bit 0, see Page 61.
Measuring system – position ascending clockwise
(looking at shaft, flange connection)
Measuring system – position descending clockwise
(looking at shaft, flange connection)
6.2.3.6 Encoder Class 4 functionality
Alternatively, this parameter can also be set during operation via an acyclic parameter access to the
function control PNU 65004 Bit 1, see Page 61.
The parameters and functions Scaling function
control, Preset and Code sequence are generally
disabled.
The parameters and functions Scaling function
control, Preset and Code sequence are generally
enabled.
The settings have a direct influence on the position output in
G1_XIST1, G1_XIST2 (if enabled via control word G1_STW,
bit 13) and G1_XIST3. The preset function is also only
effective in G1_XIST1, if the parameter Preset affects
XIST1 is set to enable.