6.2.3 Configurable module-related parameters
The parameters of the modules Channel 1 (PNO) and Channel 2 (PNO) can be set according
to the following table via an input box in the configuration tool and are automatically sent by the control
to the measuring system during start-up via the record data object with index 0xBF00.
Byte
Parameter
Data type
Description
Page
0-1
Parameter
initialization
(PNU 65005_0-1)
Bit range
Bit 0-1
Parameter initialization controller
0: PRM Data Block
1: RAM Data
Class 3 and 4
45
Parameter Write
protection
(PNU 65005_2-4)
Bit 2-4
Parameter access control
0: Write all
1: Read-only
Class 3 and 4
45
Write protection
(PNU 65005_5)
Parameter Control
(PNU 65005) +
Save parameter
(PNU 971)
Bit 5
Access control to parameters PNU
65005 and PNU 971
0: Write all
1: Read-only
Class 3 and 4
45
Write protection
(PNU 65005_6) for
Parameter Reset
(PNU 972)
Bit 6
Access control to parameters
PNU 972
0: Write all
1: Read-only
Class 3 and 4
45
2
Rotational
direction
Unsigned8
Bit 0
Counting direction
0: CW
1: CCW
Class 4
46
Encoder Class 4
functionality
Bit 1
Enable Class 4 functionality
0: disable
1: enable
Class 4
46
Preset affects
XIST1
Bit 2
Preset affects for signal G1_XIST1
0: enable
1: disable
Class 4
47
Scaling function
Bit 3
Enable scaling
0: disable
1: enable
Class 4
47
Alarm channel
control
Bit 4
Enable via alarm channel control
0: disable
1: enable
(only in compatibility mode)
47
Compatibility mode
V3.1
Bit 5
Compatibility with Encoder Profile
V3.1
0: enable
1: disable
Class 3 and 4
48
Continued on next page