Overview
5–2 iSTAR eX Installation and Configuration Guide
Overview
The ICU provides iSTAR eX configuration, diagnostic, and troubleshooting
options.
Use the ICU to designate the master controller, define master IP addresses,
and define the IP address for the C•CURE host. Other configuration
information should be defined and downloaded from the C•CURE host.
However, sites that use locked IP addresses to provide local management can
use the ICU utility for local cluster configuration.
To ensure correct configuration, the information that you enter in the ICU
must match the information that you enter in the C•CURE Administration
application.
NOTE
Software House recommends that you use the ICU only for initial setup of
master controller address information and for occasional troubleshooting.
This is because configuration information in the C•CURE is downloaded
to iSTAR eX and overwrites the values that you specify in the ICU.
NOTE
UL has not evaluated or approved the ICU utility.