iSTAR eX Installation and Configuration Guide 5–3
Configuring a Master Controller
Use the ICU to define the controller type (master), the controller IP address,
the primary connection type, and the C•CURE address.
For LAN configurations, Software House recommends that you configure
information for member controllers in the C•CURE Administration
application. The C•CURE downloads member configuration information to
the master at start-up, and the master uses the information to configure the
member controllers.
Troubleshooting Tools
The ICU provides a set of troubleshooting tools that help you to monitor the
iSTAR eX network. Use troubleshooting tools to:
PING IP addresses.
Send messages to other ICU users.
Open a Real Time Monitor Controller Diagnostic window within the
ICU and display reports and diagnostic messages.
C•CURE 800/8000 Configuration Diagnostics
The ICU provides a diagnostic command that verifies the following items on
the local computer which is running the ICU:
C•CURE 800/8000 host version
C•CURE 800/8000 ccure.ini file
Windows services file
Host TCP/IP connection
NOTE The configuration test is only for the C•CURE 800/8000.