Installation Requirements
iSTAR eX Installation and Configuration Guide 3–9
Third Party Readers
Table 3.7 shows power requirements for third party readers.
Wyreless Products
The Wyreless PIM and Access Point Modules (WAPMs) provide wireless
door monitoring on C•CURE 800/8000 systems. Only the PIM is directly
connected via RS-485 to the iSTAR eX controller. Power requirements for the
Wyreless PIM-OTD-485 are 300mA@ 12VDC.
Table 3.7: Third Party Reader Power Requirements
Reader Current Draw at 12VDC
Indala Flex Pass Series 65 mA
Sensor Eng WR1, WR2 30 mA
HID MiniProx 60 mA
HID ProxPro 100 mA
HID MaxiProx 200 mA
HID iCLASS 100 mA
NOTE
HID MiniProx has been evaluated by UL for use with iSTAR eX. The other
third party readers have not been evaluated by UL for use with iSTAR eX.
NOTE
Wyreless products have not been evaluated by UL for use with iSTAR eX.
NOTE
The C•CURE 9000 does not support Wyreless PIMs connected to the
iSTAR eX.