Page 119
FIGURE 58
In a leak test using flow, there is the option of using fill time (shown in
Figure 58) or going straight to test phase. Fill time is usually needed for
large parts that need to fill with air before they start flowing. Small parts
can often do without fill time because they fill up and start flowing
immediately. The flow rate is displayed for both during the fill and test
phases.
Figure 58 shows a leak test using flow.
Because the flow was between the
minimum and maximum flow setpoints at
then end of test time, the product passed
and PASS is displayed in the status box
on the run display.
.0 PASS
Test Time Status
PROGRAM 2
Press. Tested Reject