Pressure Decay Parameters
Parameters that must be set in a pressure decay test:
Test Pressure
Pressure Error
Coupling Time
Fill Time
Stabilization Time
Test Time
Dump (auto, off or time)
Reject Level (maximum decay)
Product Volume (optional, to calculate cc/m)
Next Program
FIGURE 38
Back Prev Next Inc Dec
PROGRAM 1
Test Type PD
Test Press. 14.999 psig
Press. Error .5 psig
Coupling GoTo
Test Params GoTo
Next Program 0
PRESSURE DECAY TEST
Fill Time 2.0 sec
Stab Time 1.0 sec
Test Time 3.0 sec
Dump AUTO
Rej Level .050 psig
Product Vol. 1.0 cc
.51 ccm
Coupling Timer Setup
Time CP1
1st .5 ON
2nd .0 OFF
Occ Rel NO
Hld/Fail NO