Watlow F4T 268 Chapter 6 Appendix
Parameter Class
and Name
Range Default
Data Type and
Attributes
Modbus Registers
Start Profile Number
33
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18550
Start Profile 33 using
'Start(1782)'"
Start Profile Number
34
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18552
Start Profile 34 using
'Start(1782)'"
Start Profile Number
35
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18554
Start Profile 35 using
'Start(1782)'"
Start Profile Number
36
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18556
Start Profile 36 using
'Start(1782)'"
Start Profile Number
37
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18558
Start Profile 37 using
'Start(1782)'"
Start Profile Number
38
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18560
Start Profile 38 using
'Start(1782)'"
Start Profile Number
39
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18562
Start Profile 39 using
'Start(1782)'"
Start Profile Number
40
"None (61)
Start (1782)
Calendar Start (1783)"
None (61)
"unsigned 16-bit
Access = RW"
"18564
Start Profile 40 using
'Start(1782)'"
Guaranteed Soak
Deviation 1
(0 to 9,999°F or units)
(0 to 5,555°C)
10.0°F or units
5.6°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19086
affects all steps of
current profile
Guaranteed Soak
Deviation 2
(0 to 9,999°F or units)
(0 to 5,555°C)
10.0°F or units
5.6°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19088
affects all steps of
current profile
Guaranteed Soak
Deviation 3
(0 to 9,999°F or units)
(0 to 5,555°C)
10.0°F or units
5.6°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19090
affects all steps of
current profile
Guaranteed Soak
Deviation 4
(0 to 9,999°F or units)
(0 to 5,555°C)
10.0°F or units
5.6°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19092
affects all steps of
current profile
Step Type
"Soak (87)
Ramp Time (1928)
Ramp Rate (81)
Wait For (1542)
Instant Change (1927)
Jump (116)
End (27)"
Soak (87)
"unsigned 16-bit
Access = RW"
"Profile Editor Step 1:
19094
Profile Editor Step n:
19094+((n-1)* 170)"
Hours 0 To 999 0
"unsigned 16-bit
Access=RW"
"Profile Editor Step 1:
19096
Profile Editor Step n:
19096+((n-1)* 170)"
Minutes 0 To 59 0
"unsigned 8-bit
Access=RW"
"Profile Editor Step 1:
19098
Profile Editor Step n:
19098+((n-1)* 170)"