Watlow F4T 269 Chapter 6 Appendix
Parameter Class
and Name
Range Default
Data Type and
Attributes
Modbus Registers
Seconds 0 To 59 0
"unsigned 8-bit
Access=RW"
"Profile Editor Step 1:
19100
Profile Editor Step n:
19100+((n-1)* 170)"
Jump Step
1 To Current Step -1
(Minimum of 1)
1
"unsigned 8-bit
Access=RW"
"Profile Editor Step 1:
19102
Profile Editor Step n:
19102+((n-1)* 170)"
Jump Count 0 To 9999 1
"unsigned 16-bit
Access=RW"
"Profile Editor Step 1:
19104
Profile Editor Step n:
19104+((n-1)* 170)"
Rate Loop 1
0 to 9,999°F or units
0 to 5,555°C
0.0
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19106
Profile Editor Step n:
19106+((n-1)* 170)"
Rate Loop 2
0 to 9,999°F or units
0 to 5,555°C
0.0
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19108
Profile Editor Step n:
19108+((n-1)* 170)"
Rate Loop 3
0 to 9,999°F or units
0 to 5,555°C
0.0
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19110
Profile Editor Step n:
19110+((n-1)* 170)"
Rate Loop 4
0 to 9,999°F or units
0 to 5,555°C
0.0
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19112
Profile Editor Step n:
19112+((n-1)* 170)"
Target Set Point Loop
1
-99,999.000 to
99,999.000°F or
units, -55,572.778 to
55,537.222°C
0°F or units
-17.8°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19114
Profile Editor Step n:
19114+((n-1)* 170)"
Target Set Point Loop
2
-99,999.000 to
99,999.000°F or
units, -55,572.778 to
55,537.222°C
0°F or units
-17.8°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19116
Profile Editor Step n:
19116+((n-1)* 170)"
Target Set Point Loop
3
-99,999.000 to
99,999.000°F or
units, -55,572.778 to
55,537.222°C
0°F or units
-17.8°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19118
Profile Editor Step n:
19118+((n-1)* 170)"
Target Set Point Loop
4
-99,999.000 to
99,999.000°F or
units, -55,572.778 to
55,537.222°C
0°F or units
-17.8°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19120
Profile Editor Step n:
19120+((n-1)* 170)"
Wait For Process 1
Condition
If digital: None (61), On
(63), Off (62)
If analog: None (61),
Above (1964), Below
(1965)
None (61)
"unsigned 16-bit
Access = RW"
"Profile Editor Step 1:
19122
Profile Editor Step n:
19122+((n-1)* 170)"
Wait For Process 1
Value
-99,999.000 to
99,999.000°F or
units, -55,572.778 to
55,537.222°C
0°F or units
-17.8°C
"IEEE Float
Access=RW"
"Profile Editor Step 1:
19124
Profile Editor Step n:
19124+((n-1)* 170)"
Wait For Process 2
Condition
If digital: None (61), On
(63), Off (62)
If analog: None (61),
Above (1964), Below
(1965)
None (61)
"unsigned 16-bit
Access = RW"
"Profile Editor Step 1:
19126
Profile Editor Step n:
19126+((n-1)* 170)"