CHAPTER 8 - CFW-09 OPTIONS AND ACCESSORIES
At start-up, program Parameter
– Type of Control = 4 (Vector with
Encoder) to operate the motor with incremental encoder speed feedback.
For more details about Vector Control operation refer to chapter 5.
TheExpanded I/OBoardsEBAand EBB areprovidedwith externallypowered,
isolated encoder output signals.
Connector XC9 Descripition
Max. Recommended lenght: 100 m (300 ft)
Connector XC9 (DB9 - Male)
Power supply voltage 12 Vdc / 220 mA for encoder.
Referenced to ground via 1
Valid pin position with encoder HS35B models from Dynapar. For other encoder modules,
check the correct connection to meet the required sequence.
Connector XC8 (DB9 Female)
*For on external power supply: 5 V to 15 V
Consumption: 100 mA @ 5 V, outputs not included.
Optionally, the external power supply can also be connected via:
XC4:19 and XC4:20 (EBA) or
– Encoder signals repeater output
The max. permitted encoder frequency is 100 kHz.
Sequence of the encoder signals:
There is no internal power
supply for XC8 at EBA or EBB board.