DETAILED PARAMETER DESCRIPTION
This chapter describes in detail all CFW-09 parameters. In order to simplify the
explanation,the parameters havebeengroupedbycharacteristicsandfunctions:
Symbols and definitions used in this chapter:
Indicates that the parameter can be changed onlywith the inverter disabled
Indicates thatthe valuescan change as a function of the motor parameters.
Indicates that the values can change as a function of P413 (Tm Constant -
obtained during Self-tuning).
Indicates that the values can change as a function of P409, P411
(obtainedduring Self-tuning).
Indicates that the values can change as a function of P412 (Tr Constant -
obtained during Self-tuning).
Indicates that the values can change as a function of P296.
Indicates that the values can change as a function of P295.
Indicates that the values can change as a function of P203.
Indicates that the values can change as a function of P320.
(For new inverters) User Default = no parameters.
The inverter will be delivered with settings according to the market,
considering the HMI language, V/F50 Hz or 60 Hzand the required voltage.
Thereset of thestandardfactorysettingmaychange the parameters related
to the frequency(50 Hz/60 Hz). Values within parenthesis mean the factory
The maximum value of P156 and P401 is 1.8 x P295 for model 4.2A/500-
600 V and 1.6 x P295 for models 7 A and 54 A/220-230 V; 2.9 A and 7 A/
500-600 V; 107A, 147Aand 247A/500-690 V; 100A, 127Aand 340A/660-
it is the component of the motor total current responsible
torque generation (used in Vector Control).
= it is the component of the motor total current proportional
to active electric power absorbed by the motor (used in V/F control).
Variables that can only be viewed on the
display but not changed. Examples
would be motor speed or motor current.
Programmable values used by the
CFW-09 functions. Examples would be
Acceleration and Deceleration times.
Set-up parameters that are programmed
during inverter start-up and define its basic
operation. Examples would be Control
Type, Scale Factors and the Input/Output
Motor data that is indicated on the motor
nameplate. Other motor parameters are
automatically measured or calculated
during the Self-tuning routine.
Special Function Parameters
It includes parameters related to special