EasyManua.ls Logo

WEG CFW-09 - Page 115

WEG CFW-09
362 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
116
CHAPTER 5 - START-UP
NOTE!
The inverter always stores the last speed reference value set through the keypad.
Therefore, if you want to change this value before enabling the inverter use the
parameter
P121
- Keypad Speed Reference.
NOTES!
(1)
P401 maximum value is 1.8 x P295 for model 4.2 A/500-600 V and 1.6 x P295
for models 7A and 54 A/220-230 V; 2.9 A and 7 A/500-600 V; 107 A, 147 A and
247 A/500-690 V; 100 A, 127 A and 340 A/660-690 V.
(2)
The last speed reference value set via the
and
keys is saved.
If you wish to change this value before enabling the inverter, change parameter
P121
(KeypadReference).
(3)
If the direction of rotation of the motor is inverted, power the
inverter
down, waits
10 minutes for the complete discharge of capacitors and interchange any two
motor output cables.
(4)
Incase of having E01duringdeceleration, increasethe decelerationtime through
P101 / P103.
ACTION
LED DISPLAY
DESCRIPTION
LCD DISPLAY
VFD
ready
VFD
ready
Motor decelerates
(4)
down to 0 rpm
and then reverses the direction of
rotation accelerating back up to
1800rpm
Motor decelerates down to 0 rpm
Motor accelerates from 0 rpm up to the
speed set at P122
Ex.:
P122 = 150 rpm
CCW direction of rotation
Motor decelerates down to 0 rpm
Press the FWD / REV key
Obs.:
The LEDs on the keypad
show whether the motor is running
FWD or REV
Press the Stop key
Press the key and hold it
Release the key
Motor Speed
P
0
0
2
=
1
800 r
p
m
Motor Speed
P
0
0
2
=
1
50
r
p
m

Table of Contents

Other manuals for WEG CFW-09