3. Optional: If your selected piercing method is 3-Segment, set Piercing
parameters in Layer number-Arris Parameters page:
– Check 1st Segment, 2nd Segment and 3rd Segment. The system
executes three-segment piercing from the first to the third.
If any segment is unchecked, the system skips this segment.
– Check Increment S and set the parameter.
Increment S: the speed of the cutting head during falling to the cutting
height.
If it is unchecked, the cutting head follows to cutting height.
– Check Extra Blow and set Delay and Pressure. The system executes
blowing without laser on after piercing.
If Extra Blow is unchecked, the system executes blowing with laser on
after piercing.
6.2.2 Adjust the Power Curve
This operation is used to make the cutting power changes with speed accordingly
and ensure thermal power absorbed in unit area is the same and achieve fine cutting
result, so as to solve problems like over-burning around the corner and difference of
cutting result in terms of thickness.
Before adjusting the curve, check Enable Auto Adjust in Power Curve area. The
system adjusts the speed to the power automatically based on the curve without
other manual operations. Otherwise, the power remains the same.
To adjust the power curve in Power Curve area, do the following:
1. Click Edit. Edit dialog box pops up: