PROSINE 2.0 INVERTER•CHARGER USERS MANUAL
76
445-0089-01-01
Inv Low Batt Vlt Low battery voltage, invert
mode.
Check battery state of charge and re-charge if
necessary.
Check for proper DC cable size.
Check all connections for tightness.
Inv High Bat Vlt High battery voltage, invert
mode.
Check for external charging sources and
disable if necessary.
Chg High Bat Vlt Charger high battery voltage.
ACInRevPolarity Input AC line and neutral
wiring polarity is reserved.
Check to see that the Line side
of the AC source
(shorepower) has a voltage to
ground and the neutral side
does not.
The unit will continue to operate. For safest
operation, however, you should correct the
AC input polarity
AC Out Overload AC output overload. Reduce the AC load so that even for short
times, AC output current does not exceed
26A.
AC In V Too Low AC input voltage too low. Check for bad cabling.
There may be too many loads on the AC
supply line.
Reduce the AC dropout level.
AC In V Too High AC input voltage too high. Check the AC input (shorepower) source
voltage and correct if necessary or raise the
AC input high voltage limit.
Bat Tmp SnsrShrt Battery temperature sensor
short detected.
Install a new sensor.
Memory Warning EEPROM memory CRC is
incorrect
Call Xantrex.
Equalizing! The unit is equalizing.
Refer to
page 122
: disconnect any sensitive
loads and monitor battery electrolyte level
and S.G. throughout.
Unit will now
attempt to restart
after an error
occurs.
Auto Restart After Error has
been enabled.
The unit will re-start and provide 120VAC
output without warning.
Disconnect any AC loads that could be
hazardous if they were to become re-
energized without warning.
Unit attempting to
restart.
Auto Restart After Error has
been enabled, the error has
cleared, and the unit is
restarting.
Table 8 Warning Messages
Warning Message Details Action

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex PROsine 2.0 and is the answer not in the manual?

Xantrex PROsine 2.0 Specifications

General IconGeneral
BrandXantrex
ModelPROsine 2.0
CategoryInverter
LanguageEnglish

Related product manuals