PROSINE 2.0 INVERTER•CHARGER USERS MANUAL
48
445-0089-01-01
Configure PROsine—Advanced Menu
Menu Choices or Information Displayed
Load Sensing
Select Enabled if you want the unit to periodically search for the
presence of an AC load while it is inverting. The unit will “sleep” if
the load it detects is less than the Load Sensing setting.
Select Disabled if you do not want the unit to search for an AC load.
For further information about load sensing, see “Load Sensing Mode”
on page 64.
Load Sense Power
This setting determines what power the inverter needs to detect
before it will start automatically (if Load Sensing is Enabled).
Settings range between 10 and 255W.
Menu Items Access
Load Sensing
User
Load Sense Power
User
Load Sense Interval
User
Low AC Transfer (V)
User
Low AC Transfer (Hz)
User
High AC Transfer (V)
User
High AC Transfer (Hz)
User
AC Series Mode
Installer
Inverter Low V Shutdown
User
Run Without Panel
User
Inverter Enabled on Reset Without
Panel
User
Charger Enabled on Reset
Without Panel
User
Auto Restart After Error
User
Reset to Defaults:
Load Factory
Save Custom
Load Custom
Installer
Installer
Installer