PROSINE 2.0 INVERTER•CHARGER USER’S MANUAL
78
445-0089-01-01
Error Messages
Error messages indicate that there has been a change in system operation due
to a detected condition.
• You can retrieve the previous twenty Error messages by placing the unit
in Configure mode and then selecting View Last 20 PROsine Faults from
the Diagnostics menu.
• To clear an Error message, press the ESCAPE key.
• If the audible alarm is enabled, press ESCAPE twice. The first key press
deactivates the alarm and the second removes the message from the
screen. (The error is not cleared from the system, however.)
Some Error messages appear as
Internal Error nnnn
where nnnn is the number of the error.
If one of these errors causes the
inverter•charge
r to shut down, attempt to
restart the unit. If the error occurs again, call Xantrex.
Other errors are listed in Table 9. The text in the Error Message column
appears as the second line on the LCD; the first line displays PROsine Error.
Table 9 Error Messages
Error Message Details Action
Internal Error 2817 Low bus voltage detected Clear the error in the
Configure
menu and
then recharge the batteries.
If the problem persists, contact Xantrex.
Battery Too Hot PROsine battery temperature
too high.
Check the tightness of all connections.
Check electrolyte level.
Check charger and battery settings.
Battery TooCold PROsine battery temperature
too low.
Extreme cold may require a battery heater. If
the battery is frozen, thaw it gradually to
avoid damage.
Int.Temp1 TooHot PROsine internal temperature
1 too high. Reduce the loads on the system.
Ensure that the PROsine is being adequately
ventilated.
Int.Temp2 TooHot PROsine internal temperature
2 too high.
Int.Temp1TooCold PROsine internal temperature
1 too low.
Raise the ambient temperature.
Int.Temp2TooCold PROsine internal temperature
2 too low.